Product Description
The cold roll-forming process used in producing the AP Rib profile metal roofing sheet ensures a high degree of consistency and dimensional accuracy in the end product. The AP Rib profile has an excellent strength weight ratio, durable and cost effective.
Applications
This product is widely used for commercial and industrial applications like factories, shop lots and apartments. Besides being used as metal roofs, AP Rib is equally suitable for use as cladding and fascia or even hoarding.
Materials Available
- Clean Colorbond® Steel
- Zincalume® steel
- PrimaMajuTM steel
- Pre-painted Galvanised Iron (PPGI)
SECTIONAL PROFILE

Dimensions Tolerance
Rib height : 25mm Thickness for material : + 0.03mm
Effective cover : 762mm Effective width : + 3mm
Minimum roof pitch : 3° Finishing length : + 5mm
TECHNICAL DATA
AVAILABLE THICKNESS
|
Base Metal
Thickness
(mm) |
Total Coated
Thickness
(mm) |
Weight
(kg/m2) |
Steel
Grade |
Min. Yield
Strength
(MPa) |
|
0.35 |
0.40 |
3.46 |
AS1397 |
G550 |
|
0.42 |
0.48 |
4.20 |
AS1397 |
G550 |
|
0.48 |
0.55 |
4.76 |
AS1397 |
G550 |
other thicknesses are subject upon stock availability and time delivery
RECOMMENED MAXIMUM ROOF LENGTH (M)
|
Slope in Degree
Rainfall (mm/h) |
3° |
5° |
7° |
|
150 |
50 |
60 |
80 |
|
200 |
39 |
50 |
60 |
|
250 |
30 |
40 |
48 |
|
300 |
26 |
30 |
40 |
RECOMMENDED MAXIMUM SPACING OF SUPPORT
|
Base Metal
Thickness
(mm) |
Total Coated
Thickness
(mm) |
ROOFS |
WALLS |
|
End Span
(mm) |
Internal Span
(mm) |
End Span
(mm) |
Internal Span
(mm) |
|
0.35 |
0.40 |
900 |
1000 |
1200 |
1500 |
|
0.42 |
0.48 |
1200 |
1500 |
1700 |
2000 |
|
0.48 |
0.55 |
1300 |
1700 |
2000 |
2300 |
INSTALLATION METHOD

It is strongly recommended that sheets are laid with the side laps facing away from the direction of the prevailing wind. Where possible, the roof sheets should be fixed with the side laps facing away from the normal line of sight.
SIDE LAP AND FLASING Side lap fasteners are required at mid spans for purlin spacings over 1,000mm and for girt spacings over 1,200mm. For all side lap and flashing fastening, use no. 10 x 25mm self drilling Hexagon Head Screw with pre-assembled neoprene bonded steel washer.
END LAPS AP RIB is available in continuous length limited only by the maximum transportable length of 20m. For longer length, end lap is necessary. Minimum end lap should be 200mm and for roof pitches below 8º, the lap should be treated with a recommended sealant.
FIXING
CREST FIXING OF AP RIB


Crest fixing to steel Crest fixing to timber
No. 12 x 45mm self drilling and No. 10 x 59mm self drilling and
tapping Hexagon Head Screw with Hexagon Head Screw with
pre-assembled neoprene bonded Pre-assembled neoprene bonded steel
steel washer. steel washer.
VALLEY FIXING OF RIB

Valley fixing to steel Valley fixing to timber
No. 10 x 20mm self drilling and No. 10 x 25mm self drilling and
tapping Hexagon Head Screw with Hexagon Head Screw with
pre-assembled neoprene bonded Pre-assembled neoprene bonded
steel washer. steel washer.
ACCESSORIES
 
Parapet or End Wall Flashing Fascia Flashing

Hip Capping

Fascia Flashing

Parapet or End Wall Flashing
|